If your heat pump is blowing cold air in New Port Richey, it is usually one of four things: a normal defrost cycle, a thermostat set to cool or fan on, an outdoor unit that is iced up or not running, or a refrigerant or reversing valve problem. The first two you can check yourself in a minute.
Is it just the defrost cycle?
On a cold, damp morning, frost builds up on the outdoor coil. To clear it, the heat pump briefly flips into cooling mode, so the air at your vents can feel cool. You may see steam coming off the outdoor unit and its fan stop.
That is normal. Lennox says a typical defrost cycle lasts about 5 to 15 minutes, and many systems bring on backup heat strips during it. Then warm air comes back on its own.
Not normal: cool air well past 15 minutes, or a coil that stays caked in ice. That points to a defrost control, sensor or airflow problem.
Is the thermostat set right?
It is the first thing I check on these calls, because it is the cheapest fix there is.
- Mode. It should say Heat, not Cool or Auto.
- Fan. If the fan is set to On, the blower runs nonstop and moves unheated air between cycles. Set it to Auto.
- Setpoint. Set it a few degrees above room temperature so it actually calls for heat.
- New thermostat? If the cold air started after a thermostat swap, the heat pump setting may be backwards. Most heat pumps switch the reversing valve in cooling, but Rheem and Ruud switch it in heating, per Honeywell's support pages. Get it wrong and you get cold air when you ask for heat.
If all of that checks out and it still blows cold, the problem is in the equipment.
Heat pump blowing cold in New Port Richey? Call and I'll come take a look.
Ryan Ferguson, Florida Certified Air Conditioning Contractor, license CAC1822213 | West Florida Air
What does it mean if the outdoor unit is iced up or not running?
It is not running. If the indoor fan blows but the outdoor unit is silent, it is not making heat. Check the breaker and the disconnect next to the unit. Reset a tripped breaker once. If it trips again, leave it off and call. A repeat trip means something electrical is wrong.
It is covered in ice. Light frost that comes and goes is normal. Solid ice that never clears means it is not defrosting, airflow is blocked, or it is low on refrigerant. Do not chip at it. The coil is easy to puncture.
Aux Heat is always on. The heat strips are covering for a heat pump that is not keeping up. The strips cost more to run, and if they are out too, the air feels cold.
Could it be low refrigerant or a bad reversing valve?
Yes, and both need a licensed tech.
Low refrigerant. A heat pump does not use up refrigerant. If it is low, it is leaking, and it will heat poorly and can ice over. The real fix is finding the leak.
Reversing valve. This valve switches the heat pump between heating and cooling. If it sticks in cooling, or the coil that moves it fails, you get cold air no matter what the thermostat says. Sometimes it is just the coil. Sometimes the valve has to be replaced, which is a bigger job.
I test before I quote anything. If the unit is old enough that a big refrigerant repair is not worth it, I'll tell you that. You can read more about my heat pump repair service.
Why does this show up on the first cold morning in New Port Richey?
Here in Pasco County, most heat pumps spend the year cooling. Heat can go unused for months, so the first chilly morning is when a sticky reversing valve, a bad defrost board or dead heat strips finally shows up.
Most of Pasco County is on Duke Energy Florida, and a heat pump leaning on its backup strips all winter will show up on that bill.
If the system does need replacing, Florida requires a licensed contractor and a county or city mechanical permit for it. See my pages for heating repair in New Port Richey and AC repair in New Port Richey.
When should I call right away?
Call now, not next week, if:
- You smell burning or see smoke that is not white steam from defrost
- The breaker trips again after one reset
- The outdoor unit stays iced solid or will not run at all
- Aux Heat is on constantly and the house still will not warm up
- Someone in the home is elderly, sick or very young and the house is getting cold
If it blows cool for a few minutes and then warms up, you can wait and watch. If it keeps happening, book a visit before the next cold snap.
FAQ
Is it normal for a heat pump to blow cold air for a few minutes?
Yes, during a defrost cycle. The system briefly runs in cooling mode to melt frost off the outdoor coil. It should clear on its own in a few minutes.
What is the difference between aux heat and emergency heat?
Aux heat comes on automatically when the heat pump needs help, like during defrost. Emergency heat is a setting you choose that runs only the electric strips. Use it only when the heat pump is down, because it costs more to run.
Can I add refrigerant myself?
No. Adding refrigerant takes EPA Section 608 certification, and low refrigerant means there is a leak. Topping it off without fixing the leak puts you right back here.
Should I turn the system off if it keeps blowing cold?
If the outdoor unit is iced solid, the breaker keeps tripping, or you smell burning, turn it off at the thermostat and call. Otherwise switch to emergency heat to stay warm until it gets looked at.
What should I do next?
Check the thermostat mode and fan setting first. If those are right and it still blows cold, call me at (727) 857-3051 or request a free estimate. I'm the one who shows up, and I'll tell you straight whether it is a quick fix or not.